 iLS120-ON Plug- in amps on-switched relay with low current 120volt trigger cord:
This 120 volt AC Module can switch on 120 volt AC equipment while another is being activated. Switch on air-venting fans when light are on. Easy to set-up. $54.95 |  iLS120-OFF Plug-in 12 amps on-switced relay with low current 120 volt trigger cord:
This 120 volt AC Module can switch off 120 volt AC equipment while another is being activated. Switch off fans, while CO2 or sulfur vaporizing is in progress or dehumidifier when fans are on. Easy to set-up. $54.95 |
 Automatic Dialer & Movement Detector Alarm:
The iMS100 is a security system which will detect intruders and fires in your home, office, business or wherever it is set up. It is designed to give you an early warning by calling up to 6 pre-stored phones/pager with your own voice message. It is simple to set up and use, and will monitor your home or business without any monthly charge. $184.95 |  CO2 Control With Auxiliary Shut Off Output iGS-100:
The iGS-100 CO2 controller is an essential control tool to efficiently and economically use CO2 enrichment for higher growth rates or to fulfill minimum ventilation needs day and night. The display shows the ambient CO2 concentration within 75ppm at all times. The internal CO2 infra-red sensor reads values from 0 to 5000 ppm. The air sampling is optimized by means of an integrated fan. The control unit can be positioned up to 6 feet from the output box (a cable up to 50 feet can be used). The controller will automatically adjust its operating differential when the CO2 concentration overshoots or undershoots the desired set point. Two set points are used by the controller : day and night set points. This unit is 120 volts and uses 12 watts of power.
Maximum load both outputs: 15 A 120 Vac.
Battery-backed microprocessor control.
Sensor and Control range : 0-5000 ppm.
Automatic differential compensation: 20 ppm.
Annual drift of the CO2 sensor: 75 ppm.
Calibration of the CO2 sensor: 1 year. $539.95 |
 CO2 Control with High Temperature Shut Off Function:
The iGS-061 will perform CO2 enrichment during the day only (when light is sensed by the photocell). The enrichment starts when the CO2 concentration falls below the set point minus the differential. (i.e. Set point = 1200 ppm Differential = 150, CO2 enrichment starts below 1050 ppm and stops beyond 1350 ppm). The differential modifies itself until the controller senses no more overshooting or undershooting of user set point. Fixed differential values can also be set for more specific needs. As a safety feature, the high temperature shut off function will inhibit operation while temperature is over the user setting. This interruption is maintained until temperature falls below the user high temp setting. To inhibit this feature, simply set the limit to its highest value. The controller can also be set to vent (extract) CO2. In this case, the high temp shut off feature becomes a low temp shut off limit to prevent excessive cooling conditions. $444.95 |  Day & Night Cooling & Dehumidifying Control with Display:
The iGS040 Cooling and dehumidifying controller will operate your inlet and/or exhaust fans (or any other cooling and/or dehumidifying equipment) in accordance to user temperature and relative humidity day and night set points. Temperature and relative humidity values can be viewed in real time on the luminous bar graph. The differential is factory preset to 2.5% for RH and 1C for temperature. Of course these values can be increased by the user. This controller also offers the user a low temperature limit which when set will interrupt the equipment in the case of excessive cooling. One year warranty $191.95 |
 Day & Night Temperature & Relative Humidity Control iGS-110:
The iGS-110 temperature and relative humidity controller is essential to good climate control in a grow room or greenhouse. Good climate control is the cornerstone of a fast growing garden and is the first line of defense for pest and disease prevention. The display shows the ambient temperature (Celsius and Farenheit) and relative humidity values. The internal sensors benefit from a fast sampling rate. The control unit can be positioned up to 6 feet from the output box (a cable up to 50 feet can be used). Multiple operation modes are available and the differential of operation is adjustable. This unit is 120 volts and uses 12 watts of power.
One year warranty
Features :
Maximum load both outputs: 15 Amp 120 volt AC.
RH Sensor and control range: 0%-100%.
Auto differential adjustment: 3 to 10%.
Annual drift: 1%.
Accuracy of RH sensor: 3%.
Calibration of RH sensor: factory calibrated.
Temperature sensor and control range: -20C to +50C (-4F to +122F).
Auto. Differential adjustment: 1C to 10C (-1,8F to +18F).
Accuracy of temperature sensor: 1C (2F).
Resolution of temperature sensor: 0,5C (1F).
Calibration of temperature sensor: factory calibrated. $259.95 |  iGS-010 Day & Night Cycle Timer with Photocell & Display:
The iGS-010 cycle controller represents an easy and flexible solution to periodic control of day and night. The integrated photocell can differentiate day and nght and will initiate the proper day or night periodic control.
ON time from 5 seconds to 60 min.
OFF time from 1 minute to 12 hours.
Maximum load : 120 volt AC, 15 Amp, 1 HP.
One year warranty. $129.95 |
 iGS-020 with Remote:
The iGS-020 temperature controller will operate your heating or cooling equipment in accordance to user day and night set points. The ambient temperature is displayed on the luminous bar graph. The precision temperature sensor (1C) can be calibrated and the differential of operation is adjustable. This controller is also available with a remote (10 feet) sensor (iGS-020R). $137.95 |  iGS-021 Day & Night Temperature Control:
Temperature controller without display.
Can be set to heat of cool with day and night setpoints. $76.95 |
 iGS-030 Day & Night Humidity Control with Display:
The iGS-030 relative humidity controller will operate your humidifying or dehumidifying equipment in accordance to user day and night set points. The ambient relative humidity is displayed on the luminous bar graph. The precision RH sensor (3%) can be calibrated and the differential of
operation is adjustable. $162.95 |  iGS-030 with Remote:
The iGS-030 relative humidity controller will operate your humidifying or dehumidifying equipment in accordance to user day and night set points. The ambient relative humidity is displayed on the luminous bar graph. The precision RH sensor (3%) can be calibrated and the differential of operation is adjustable. This controller is also available with a remote (10 feet) sensor (iGS-030R). $169.95 |
 Day & Night Cooling & Dehumidifying Control with Display with Remote:
The iGS040 Cooling and dehumidifying controller will operate your inlet and/or exhaust fans (or any other cooling and/or dehumidifying equipment) in accordance to user temperature and relative humidity day and night set points. Temperature and relative humidity values can be viewed in real time on the luminous bar graph. The differential is factory preset to 2.5% for RH and 1C for temperature. Of course these values can be increased by the user. This controller also offers the user a low temperature limit which when set will interrupt the equipment in the case of excessive cooling. One year warranty $199.95 |  iGS-070 Manual Variable Speed Control:
This module enables the user to adjust fan speed manually. Works only with magnetically driven fans. Connect up to 750 watts to a single unit. $54.95 |
 RH & Temperature Smart Control $724.95 |  Light Load Switch With Internal 0-20 Minute On Delay 240 volt Supply, 120 volt Output:
This switching module will switch up to four 1000 watt lights using a low power 120Vac trigger cord. An internal On-delay timer can be set to prevent hot bulb startups or set to sequentially turn on groups of up to four lights. This model is powered by a 240Vac circuit but delivers 120Vac to lighting ballasts (4 wires necessary from breaker assembly). $154.95 |
 Light Load Switch with Internal 0-20 On Delay 120 volt Outputs:
This switching module will switch up to four 600 watt lights using a low power 120Vac trigger cord. An internal On-delay timer can be set to prevent hot bulb startups or set to sequentially turn on groups of up to four lights. This unit is powered by 120Vac and delivers the same to the connected equipment. $146.95 |  Lighting Load Switch Box with Internal 0-20 Minute on Delay 240 volt Output:
This switching module will switch up to four 1000 watt lights using a low power 120Vac trigger cord. An internal On-delay timer can be set to prevent hot bulb startups or set to sequentially turn on groups of up to four lights. This model supplies 240Vac to your equipment. $169.95 |